Introduction

What you need

Step 1

              HEPA Filter Unit               
  • Check if the purifier’s power cord is plugged into an electrical outlet.
  • If it is plugged in, unplug the power cord.

Check if the purifier’s power cord is plugged into an electrical outlet.

If it is plugged in, unplug the power cord.

1024

Step 2

  • Grab the rear cover of the purifier with one finger on the Lock and Release button.
  • Press the button down, and pull the rear cover away from the purifier.

Grab the rear cover of the purifier with one finger on the Lock and Release button.

Press the button down, and pull the rear cover away from the purifier.

Step 3

  • Use your hands to pull the HEPA filter out of the purifier.
  • After reassembly, push & hold the UV control button for 5 seconds to reset the filter change indicator.

Use your hands to pull the HEPA filter out of the purifier.

After reassembly, push & hold the UV control button for 5 seconds to reset the filter change indicator.

Step 4

              UV-C Bulb               
  • Remove the two screws from the metal UV-C shield by turning the screws counter-clockwise using a Phillips #00 screwdriver.
  • Grab and pull the UV-C shield away from the purifier to remove it.

Remove the two screws from the metal UV-C shield by turning the screws counter-clockwise using a Phillips #00 screwdriver.

Grab and pull the UV-C shield away from the purifier to remove it.

Step 5

  • Using a tissue or a clean cloth, reach into the exposed space and grab the UV-C bulb.
  • Pull the UV-C bulb out of the exposed space to remove the bulb from its socket.
  • After reassembly, press and hold the UV control button for 5 seconds to reset the UV bulb change indicator.

Using a tissue or a clean cloth, reach into the exposed space and grab the UV-C bulb.

Pull the UV-C bulb out of the exposed space to remove the bulb from its socket.

After reassembly, press and hold the UV control button for 5 seconds to reset the UV bulb change indicator.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                                      with 1 other contributor 

                    Tim Lourenco                     

Member since: 03/28/2022

281 Reputation

                                      2 Guides authored                  



                       Badges:
                       3

Team

                       UMass Dartmouth, Team 2-1, Mellen Spring 2022                        

                                                  Member of UMass Dartmouth, Team 2-1, Mellen Spring 2022 



                    UMASSD-MELLEN-S22S2G1                     


                                            4 Members                     


                                            2 Guides authored                     

william estes - Oct 28, 2022

Reply

you end after you pull the bulb out. do you put another bulb in (of course) is there a right/wrong way (which side up or down) then do you plug it back in prior to holding the uv button 5 seconds? do you turn it on prior to holding the uv button 5 seconds? Please explain in detail what I should do.